Power Analyzers

A power analyzer is used to measure the rate of power quality flow in electrical systems, and power parameters including phase power, power factor, efficiency and harmonics. Our new power analyzers are ideal for high quality accuracy power measurement over a wide frequency range. Power measurement is from 4 channels to 32 channels, with optional speed and torque inputs, to measure both voltage and current electrical and mechanical power. Power measurement features gapless cycle by cycle detection, to support no blind spots. Hence, this is ideal for testing during dynamic load changes, where traditional power meters fail. Analysis features include real time efficiency mapping, DQ analysis, and single phase and multi-phase analysis. There are options for data transfer to a recorder or a test cell controller in a range of digital formats. All systems include the latest power analysis software for setup, real time visualisation, post processing and reporting, with free training and support available. Applications include electric and hybrid vehicle drivetrain development, renewable energy measurement and transformer testing using advanced instruments across each phase.

Download power analyzers overview POWER ANALYZERS OVERVIEW

Please wait, loading results...

Frequently Asked Questions About Power Analyzer

Need Help Choosing the Right Power Analyzer?

As you can imagine with a large proportion of engineering activities, choosing the incorrect tool may have serious implications on the results of your measurements. The information contained below is to help visitors make a more informed decision on a power analyser which is most appropriate for their requirements.

Keep up to date with everything Data Acquisition and Power through our news and blogs pages here.

Power is the rate of doing work, or the amount of energy spent per unit of time. The power of an electrical system is calculated by multiplying the measured voltage by the measured current, then integrating and dividing the result over a period of time. In order to calculate the power of an AC electrical system, the periodic time (inverse of the fundamental frequency) must be known. The term “power analysis” simply refers to the process of determining how much power is available.

A power analyzer is an instrument used to measure the rate of power flow in electrical systems. The flow of power is measured in kilojoules per second (J/s) or kilowatts (kW). Electrical power is the rate at which electrical energy is moved between two places in an electrical system per unit of time.

The method used depends on whether DC or AC power is being calculated. AC power is further broken down into three types, see below:

DC power: DC power is calculated by multiplying voltage (Volts) by current (Amps). The resultant power is measured in Watts (W). This is based on Ohm's law, and is true where the flow of current is always in the same direction.

AC power: In an alternating current (AC) circuit consisting of a source and a load, both the current and voltage are sinusoidal at the same frequency. AC power consists of active power, reactive power and apparent power.

  • Active power: Real power consumed in an AC circuit. Calculated as instantaneous voltage × current averaged over the fundamental period.
  • Reactive power: Establishes the magnetic field in motors. Represents power that bounces between source and load, not doing useful work.
  • Apparent power: The vector sum of active and reactive power; product of RMS voltage × current.

The power factor of an AC power system is defined as the ratio of the active power absorbed by the load to the apparent power flowing in the circuit, and is a dimensionless number between −1 and 1. For an induction motor at full load, power factor is typically in the range 0.85 to 0.9.

The fundamental frequency, often referred to simply as the fundamental, is defined as the lowest frequency of a periodic waveform.

A harmonic is a sinusoidal waveform with frequency that is an integer multiple of the fundamental frequency, caused by non-linear loads (e.g. rectifiers, lighting, saturated machines).

Harmonics can cause adverse effects like heating losses and higher audible noise emission in electrical systems.

Electrical energy is the product of power multiplied by the time it was consumed. Power (Watts) × Time (seconds) = Energy (Joules).

Shaft Power is the mechanical power transmitted between rotating elements in machinery. It is calculated as: Wshaft = 2 × π × (RPM/60) × Torque (Nm)

Advanced power analyzers like the Dewetron power analyzer can perform:

  • Inverter, motor, and system efficiency calculations
  • Speed-torque efficiency mapping
  • Harmonics and FFT analysis
  • DQ (Park-Clarke) transformation analysis
  • Drive cycle measurement (e.g. WLTP)
  • Synchronised vibration and sound measurement
  • Digital interfaces – CAN, EtherCAT, Ethernet
x
Loading
This Site Uses Cookies
We and our partners use cookies and mobile ad identifiers for ads personalisation, advertising measurement and audience insights. With your consent, this data may be used for personalised and non-personalised advertising.
Read about how Google uses data at business.safety.google/privacy, or see our privacy policy for more information.
Customise Accept All